CD129 / Brilliant Violet 650 / AH9R7
Product Details
Description | BV650 Mouse Anti-Human IL-9 Receptor Alpha (CD129) | |
---|---|---|
Conjugate | Brilliant Violet 650 | |
Clone | AH9R7 | |
Target Species | Human | |
Applications | FC | |
Supplier | BD Biosciences | |
Catalog # | Sign in to view product details, citations, and spectra | |
Size | ||
Price | ||
Antigen | ||
Host | ||
Isotype |
About CD129
The protein encoded by this gene is a cytokine receptor that specifically mediates the biological effects of interleukin 9 (IL9). The functional IL9 receptor complex requires this protein as well as the interleukin 2 receptor, gamma (IL2RG), a common gamma subunit shared by the receptors of many different cytokines. The ligand binding of this receptor leads to the activation of various JAK kinases and STAT proteins, which connect to different biologic responses. This gene is located at the pseudoautosomal regions of X and Y chromosomes. Genetic studies suggested an association of this gene with the development of asthma. Multiple pseudogenes on chromosome 9, 10, 16, and 18 have been described. Alternatively spliced transcript variants have been found for this gene. [provided by RefSeq, Jul 2008]
The protein encoded by this gene is a cytokine receptor that specifically mediates the biological effects of interleukin 9 (IL9). The functional IL9 receptor complex requires this protein as well as the interleukin 2 receptor, gamma (IL2RG), a common gamma subunit shared by the receptors of many different cytokines. The ligand binding of this receptor leads to the activation of various JAK kinases and STAT proteins, which connect to different biologic responses. This gene is located at the pseudoautosomal regions of X and Y chromosomes. Genetic studies suggested an association of this gene with the development of asthma. Multiple pseudogenes on chromosome 9, 10, 16, and 18 have been described. Alternatively spliced transcript variants have been found for this gene. [provided by RefSeq, Jul 2008]
About Brilliant Violet 650
Brilliant™ Violet 650 (BV650) is a red-emitting tandem fluorophore that can be excited by the 405 nm Violet laser and collected using a 660/20 bandpass filter. BV650 has an excitation peak at 405 nm and an emission peak at 645 nm. Due to its unique Stokes shift, not many dyes have identical excitation and emission spectrums, but the nearest alternatives include SuperBright 645, Qdot® 655 and eFluor™ 650NC (ThermoFisher). BV650 exhibits a medium level of brightness and is most often used in flow cytometry, specifically, it is an alternative to nanocrystals used for intracellular flow. This dye is part of the Brilliant™ Violet dye line of fluorescent polymers. Brilliant™ Violet 421 polymer is employed as the donor molecule in a series of tandem dyes with acceptor molecules emitting at various points across the visible light spectrum. The Brilliant™ Violet dyes are a superior alternative to QDot nanocrystals and similar to SuperNova dye from Beckman Coulter and StarBright dyes from Bio-Rad.
Brilliant™ Violet 650 (BV650) is a red-emitting tandem fluorophore that can be excited by the 405 nm Violet laser and collected using a 660/20 bandpass filter. BV650 has an excitation peak at 405 nm and an emission peak at 645 nm. Due to its unique Stokes shift, not many dyes have identical excitation and emission spectrums, but the nearest alternatives include SuperBright 645, Qdot® 655 and eFluor™ 650NC (ThermoFisher). BV650 exhibits a medium level of brightness and is most often used in flow cytometry, specifically, it is an alternative to nanocrystals used for intracellular flow. This dye is part of the Brilliant™ Violet dye line of fluorescent polymers. Brilliant™ Violet 421 polymer is employed as the donor molecule in a series of tandem dyes with acceptor molecules emitting at various points across the visible light spectrum. The Brilliant™ Violet dyes are a superior alternative to QDot nanocrystals and similar to SuperNova dye from Beckman Coulter and StarBright dyes from Bio-Rad.
Experiment Design Tools
Panel Builders
Looking to design a Microscopy or Flow Cytometry experiment?
Validation References
Reviews & Ratings
Reviews |
---|
Looking for more options?
301 CD129 antibodies from over 24 suppliers available with over 55 conjugates.