CD44 / Brilliant Violet 480 / IM7
Product Details
Description | BV480 Rat Anti-Mouse CD44 | |
---|---|---|
Conjugate | Brilliant Violet 480 | |
Clone | IM7 | |
Target Species | Mouse | |
Applications | FC | |
Supplier | BD Biosciences | |
Catalog # | Sign in to view product details, citations, and spectra | |
Size | ||
Price | ||
Antigen | ||
Host | ||
Isotype |
About CD44
The protein encoded by this gene is a cell-surface glycoprotein involved in cell-cell interactions, cell adhesion and migration. It is a receptor for hyaluronic acid (HA) and can also interact with other ligands, such as osteopontin, collagens, and matrix metalloproteinases (MMPs). This protein participates in a wide variety of cellular functions including lymphocyte activation, recirculation and homing, hematopoiesis, and tumor metastasis. Transcripts for this gene undergo complex alternative splicing that results in many functionally distinct isoforms, however, the full length nature of some of these variants has not been determined. Alternative splicing is the basis for the structural and functional diversity of this protein, and may be related to tumor metastasis. [provided by RefSeq, Jul 2008]
The protein encoded by this gene is a cell-surface glycoprotein involved in cell-cell interactions, cell adhesion and migration. It is a receptor for hyaluronic acid (HA) and can also interact with other ligands, such as osteopontin, collagens, and matrix metalloproteinases (MMPs). This protein participates in a wide variety of cellular functions including lymphocyte activation, recirculation and homing, hematopoiesis, and tumor metastasis. Transcripts for this gene undergo complex alternative splicing that results in many functionally distinct isoforms, however, the full length nature of some of these variants has not been determined. Alternative splicing is the basis for the structural and functional diversity of this protein, and may be related to tumor metastasis. [provided by RefSeq, Jul 2008]
About Brilliant Violet 480
Brilliantâ„¢ Violet 480 (BV480) is a green-emitting non-tandem polymer fluorophore that can be excited by the 405 nm Violet laser and collected using a 525/40 bandpass filter. BV480 has an excitation peak at 436 nm and an emission peak at 478 nm, and provides an optimized alternative to BV510. Other dyes that are similar include StarBright Violet 475 (Bio-Rad) While BV480 can be detected on the same filter as BV510, its emmision profile reduces spillover into the BV605, BV650, and BV711 channels. Additionally BV480's excitation profile will reduce cross-laser excitation with the UV laser, resulting in less spillover into UV channels than BV510. These advantages make BV480 an optimal choice for flow cytometry panels using multiple reagents on Violet and/or UV lasers. This dye is part of the Brilliantâ„¢ Violet dye line. BV510 and BV480 are the only dyes in the Brilliantâ„¢ Violet dye family that are not tandem fluorophores based off the BV421 polymer core, but they have nearly the same maximum excitation.
Brilliantâ„¢ Violet 480 (BV480) is a green-emitting non-tandem polymer fluorophore that can be excited by the 405 nm Violet laser and collected using a 525/40 bandpass filter. BV480 has an excitation peak at 436 nm and an emission peak at 478 nm, and provides an optimized alternative to BV510. Other dyes that are similar include StarBright Violet 475 (Bio-Rad) While BV480 can be detected on the same filter as BV510, its emmision profile reduces spillover into the BV605, BV650, and BV711 channels. Additionally BV480's excitation profile will reduce cross-laser excitation with the UV laser, resulting in less spillover into UV channels than BV510. These advantages make BV480 an optimal choice for flow cytometry panels using multiple reagents on Violet and/or UV lasers. This dye is part of the Brilliantâ„¢ Violet dye line. BV510 and BV480 are the only dyes in the Brilliantâ„¢ Violet dye family that are not tandem fluorophores based off the BV421 polymer core, but they have nearly the same maximum excitation.
Experiment Design Tools
Panel Builders
Looking to design a Microscopy or Flow Cytometry experiment?
Validation References
Reviews & Ratings
Reviews |
---|
Looking for more options?
3666 CD44 antibodies from over 55 suppliers available with over 138 conjugates.